Home > Arduino & SCM Supplies > Trigger
0.1 seconds (minimum) to 999 minutes (maximum) continuously adjustable This product is easy to use£¬ powerful£¬ but all buyers a detailed look at the product instructions£¬ very useful product. Features and application: 1. To achieve a high-frequency circuit fast frequent on-off switch unlimited number of times; 2. The on-off process does not produce noise£¬ no spark£¬ no electromagnetic interference; 3. life long life than conventional electromagnetic relay; 4. Dual MOS shunt active output£¬ lower resistance£¬ more current£¬ strong power£¬ 15A£¬ 400W£¬ to meet the most use of the equipment; 5. often used to control motors£¬ light bulbs£¬ LED lights£¬ DC motors£¬ micro-pumps£¬ solenoid valves£¬ etc.£¬ through this module£¬ you can easily control these devices£¬ very convenient. Module Highlights: 1. Wide voltage (5 ~ 36V)£¬ most devices can be used£¬ very convenient; 2. The interface is clear and simple£¬ powerful£¬ easy to understand£¬ meet almost all your needs; 3. There is a key stop function (STOP key)£¬ with reverse polarity protection£¬ reverse polarity does not burn; 4. Add the sleep mode function£¬ after enabling£¬ without any operation within 5 minutes£¬ turn off the monitor automatically; Any key to wake up; 5. You can set a different OP£¬ CL£¬ LOP parameters£¬ which are independent of each other£¬ were saved; 6. When all settings automatic power-down save parameters. Operating mode: P1 mode: after the trigger signal£¬ the relay is turned OP time£¬ and then disconnect; in the OP time£¬ as follows P1.1: Invalid signal triggered again P1.2: Re-timing signal is triggered again P1.3: Reset signal is triggered again£¬ the relay off£¬ stop counting; P-2: to the trigger signal£¬ relay off for time CL£¬ OP relay conduction time£¬ after the counting is finished£¬ disconnect relay; P3.1: After the trigger signal to the relay turned OP time£¬ relay off CL time£¬ then the operation cycle£¬ to signal to the relay off£¬ stop the counting once again within the loop; cycles (LOP) can be set; P3.2: After power without triggering signal£¬ the relay is turned OP time£¬ relay off CL time£¬ cycle the operation; cycles (LOP) can be set; P-4: signal holding function if there is a trigger signal£¬ timing is cleared£¬ the relay remains on; when the signal disappears£¬ after timing OP disconnect relay; timer period£¬ then there is a signal£¬ the timing is cleared; Product parameters: 1: Operating Voltage: DC 5V - 36V; 2: The trigger source: high trigger (DC 3.0V-24V) signal with no common ground system to improve anti-jamming capability of the system (also self-shorting common ground) 3: output capacity: DC 5V - 36V£¬ at room temperature£¬ continuous current 15A£¬ power 400W! Lower auxiliary cooling conditions£¬ the maximum current up to 30A. 4: Quiescent Current: 15mA 5: Availability: unlimited switch; Operating temperature: -40-85 ¡æ; 6: with optocoupler isolation£¬ enhanced anti-jamming capability£¬ industrial grade circuit boards£¬ set the parameters after power failure memory forever. pay attention: Module is active charging output£¬ the output side (load side) a voltage equal to the input terminal voltage (DC 5V - 36V). 'DC +' load '+' polarization itself is internally shorted£¬ but 'DC-' load '-' in the course of the poles can not be shorted£¬ otherwise the load can not be controlled on and off£¬ the load is equivalent to It has been carrying electricity. Timing range 0.1 seconds (minimum) to 999 minutes (maximum) continuously adjustable How to choose the time range: After setting the parameter values in the mode selection screen by a short press STOP button£¬ select the time range; XXX decimal point bits£¬ timing range: 1 second to 999 seconds XX.X decimal point in ten£¬ Timing range: 0.1 seconds to 99.9 seconds X.X.X. decimal full brightness£¬ Timing range: 1 minute to 999 minutes For example£¬ you want to set up OP is 3.2 seconds£¬ then move the decimal point to ten£¬ the digital display 03.2 Parameter Description: OP-time£¬ CL off time£¬ LOP cycles (1-999 times£¬ "---" represents infinite loop) These parameters are independent of each other£¬ but each of these common mode parameters£¬ for example£¬ P1.1 set OP-time is 5 seconds£¬ the user wants to switch to P1.2 mode£¬ then enter P1.2 set the appropriate parameters£¬ OP It will be five seconds; In the main interface (display 000) Press SET button will display OP (CL£¬ LOP) and the corresponding time XXX; If only OP mode (such as the mode P1.1£¬ P1.2£¬ P1.3) time£¬ then press SET button will display only the OP and the corresponding time; If the pattern has OP£¬ CL£¬ LOP (such as the mode P3.1£¬ P3.2) then press the SET button OP and the corresponding time£¬ CL and the corresponding time£¬ LOP and the corresponding number will be displayed; In the set mode£¬ the main interface parameters by a short press the SET button can easily see the current mode set in£¬ very convenient! How to set parameters 1. First£¬ determine the operating mode of the relay; 2. The mode of operation of the relay£¬ in the main interface (when the module is powered on£¬ flashes the current work mode (P1.1 default mode)£¬ then enter the main interface) "long press SET button for 2 seconds after the release "to enter mode selection screen by press UP£¬ DOWN buttons to select the mode to be set (P1.1 ~ P-4); 3. After selecting the mode to be set (for example£¬ P3.2) Press SET key to set the appropriate parameters£¬ then the parameter to be set flashes (OP-time£¬ CL off time£¬ LOP cycles ( "- - "represents infinite loop)) by UP£¬ DOWN to adjust the value£¬ support long press (rapid increase or decrease) and press (increase or decrease one unit); setting the parameter value by a short press STOP button to select the decimal point position£¬ select time range (corresponding time of 0.1 seconds to 999 minutes); short press sET key to set the next parameter of the current mode£¬ the process above; 4. After setting the parameters of the selected mode is good£¬ press the SET button for 2 seconds after release£¬ currently set mode will flash£¬ and then return to the main screen£¬ set the parameters of success is very simple! The main interface: In the relay does not work status display "000" (no decimal point)£¬ with a decimal point under relay state£¬ very clear! Mode selection screen: Long press SET to enter£¬ after setting is completed£¬ press SET key to exit and return to the main interface is very simple! STOP button extensions: Relays enable mode: 1. ON: inner OP-time relay allows conduction; 2. OFF: relay prohibit conduction is always closed; In the main interface£¬ short press the STOP button to switch between ON and OFF£¬ the current in which the state will flash£¬ and then return to the main screen. (This feature is an emergency stop function£¬ a key disconnect relay closed) Sleep mode: 1. C-P Sleep mode: five minutes without any operation£¬ the digital display automatically turns off£¬ the normal operation of the program; 2. O-d normal mode: digital display always open; Press STOP button for two seconds£¬ to switch C-P and O-d state£¬ in which the current state of flashes and then return to the main screen.